How the wipes are made
High-Pressure hydroentanglement is a process invented.
When using dust-free wipes, the wipe material itself may create polluting particles
(These pollutants are almost invisible)
Dust particles created by the material itself
Ions
Fibers
Crystals
Foreign pollutants on
the material
Sontara® MicroPure Cleanroom Wipes can minimize these pollutants
Sontara® MicroPure Cleanroom Wipes has excellent dry wiping and dust picking performance (because wiping dry = wiping clean)
Excellent moisture absorption
Sontara® MicroPure Cleanroom Wipes itself is made of high liquid absorption material.
Sontara®
MicroPure Wipes
Double knit edge banding
polyester cleaning wipes
Tested according to IES RP CC 004.2
Low Content Ions and Extractables
Main feature - Low content ions and extractables
Use Sontara® MicroPure Cleanroom Wipes with the correct methods to achieve the best cleaning results.
Main features:
Formed with clean water jets that wash the fibers.
No binders or chemical additives.
Ingredients:Strong, solvent resistant blend of cellulose and polyester.
Weight:68g / m2 。
Application:
Cleanroom general maintenance where high absorbency is required.
Picking up liquid spills in the cleanroom.
Polishing and cleaning or relays, contacts and switches.
Cleaning lab apparatus.
Size and Packaging:
4 "x 4 " (10.2 x 10.2 cm) - 600 wipes / pack
6 "x 6 " (15.2 x 15.2 cm) - 600 wipes / pack
9 "x 9 " (22.9 x 22.9 cm) - 300 wipes / pack
12 "x 12 " (30.5 x 30.5 cm) - 150 wipes / pack
Recommended models (Applicable to all MicroPure wipes)
* Based on the risk of pollution on the cleaning surface resulted from the manufacturing process.
Risk evaluation based on: the distance from the production line, the airflow position, the production line sensitivity, existence of other pollution sources etc.
請左右滑動表格,可查看更多欄位。
Scratch sensitivity of the surface |
Boundless, smooth surfaces |
Bounded, smooth surfaces |
Boundless, rough surfaces |
Bounded, rough surfaces |
---|---|---|---|---|
Low | Micropure AP or SL | Micropure AP or SL | Micropure AP or SL | Micropure AP |
Medium | Micropure 100 | Micropure 100 | Micropure 100 | Micropure 100 |
High | Micropure LP | Micropure LP | Micropure LP | Micropure LP |
請左右滑動表格,可查看更多欄位。
Comparison of Sontara® MicroPure Cleanroom Wipes with similar products on the market
Thickness | Roughness | Cleanliness | Absorption rate |
Absorption capacity |
Deforms after absorption |
Price | Particle generation |
|
Sontara® | Thick | Fine | High | Fast | High | No | Cheap | Low |
Similar products | Thin | Coarse | Low | Slow | Low | Yes | Expensive | High |
請左右滑動表格,可查看更多欄位。
Sontara® property sheet
Property | Sontara® MP SL |
Sontara® MP AP |
Sontara® MP 100 |
Sontara® MP LP |
Test Method |
---|---|---|---|---|---|
Composition | Lyocell | Woodpulp/ polyester |
Woodpulp/ polyester |
Lyocell/ polyester |
|
Basis weight oz/yd2(g/m2) | 1.5 (51) | 2.0(68) | 1.65(56) | 2.0(68) | ASTM D1117 Sec 17 |
Sheet Grab Tensile | |||||
MD lbs (N) | 21.4 (95) | 35.0(165) | 31.0(138) | 46.5(207) | ASTM D1117 Sec 7 |
XD lbs (N) | 15.1 (67) | 20.0(89) | 15.0(67) | 30.3(135) | ASTM D1117 Sec 7 |
Absorption Capacity | |||||
Intrinsic Ai mL/g | 8.20 | 4.27 | 4.76 | 6.85 | ASTM D6651-01 |
Extrinsic Ae mL/m2 | 418 | 276 | 267 | 465 | ASTM D6651-01 |
Absorption Rate | |||||
Intrinsic Ri mL/g/s | 150 | 34.0 | 38.0 | 27.1 | ASTM D6651-01 |
Extrinsic Re mL/m2/s | 7680 | 1755 | 2100 | 1833 | ASTM D6651-01 |
Particles | |||||
Po MM/m2 | 5.80 | 12.1 | 9.2 | 2.5 | IES-RP-CC004.2 |
BAS MM/m2 | 22.7 | 80.0 | 46.0 | 8.3 | IES-RP-CC004.2 |
Gelbo 1000/ft3 | 45.2 | 1.6 | 1.1 | INDA IST160. 1-92 | |
Extractables | |||||
Water,H2O % | 0.23 | 0.10 | 0.05 | 0.05 | IES-RP-CC004.2 |
Ispropyl Alcohol,IPA % | 0.02 | 0.03 | 0.03 | 0.04 | IES-RP-CC004.2 |
Ions | |||||
Na ppm | 22 | 18 | 13 | 5 | IES-RP-CC004.2 |
Fe ppm | 0 | 2 | 2 | 2 | IES-RP-CC004.2 |
Mg ppm | 50 | 69 | 45 | 29 | IES-RP-CC004.2 |
K ppm | 11 | 9 | 8 | 4 | IES-RP-CC004.2 |
Ca ppm | 356 | 333 | 313 | 231 | IES-RP-CC004.2 |
Fiber loss pcs(≧50μm)/ppm/m2 |
0.22 | 0.65 | 0.56 | 0.12 | ASTM D6652-01 |
Above data are for reference only. If the latest test information is needed, please contact our sales.